Cisco ASA5508-K9

Cisco ASA 5508-X FirePower services Firewall is the entry-level next-generation firewall system.It is designed for small or mid-size enterprise or branch offices. It provides 8 Gigabit Ethernet interfaces,80GB SSD, supports up to 100 IPsec VPN peers, 50,000 concurrent connections and 1 Gbps thoughtput. 

TypeCisco ASA 5508-X w/ FirePOWER Services
Throughput:Application Control (AVC)450 Mbps
Throughput:Application Control (AVC) and IPS250 Mbps
Maximum concurrent sessions100,000
Maximum New Connections per second10,000
Supported applicationsMore than 3,000
URL categories80+
Number of URLs categorizedMore than 280 million
Centralized configuration, logging, monitoring, and reportingMulti-device Cisco Security Manager (CSM) and Cisco Firepower Management Center
On-Device ManagementASDM (version 7.3 or higher required)
FeatureCisco ASA 5508-X w/ FirePOWER Services
Stateful inspection throughput (maximum)1 Gbps
Stateful inspection throughput (multiprotocol)500 Mbps
Triple Data Encryption Standard/
Advanced Encryption Standard (3DES/AES) VPN throughput3
175 Mbps
Users/nodesUnlimited
IPsec site-to-site VPN peers100
Cisco AnyConnect Plus/Apex VPN maximum simultaneous connections5100
Virtual interfaces (VLANs)50
Security contexts5(included; maximum)2; 5
High availabilityActive/
Active and Active/
Standby
Integrated Wireless Access Point(See Cisco AP 702 datasheet for WiFi technical details)N/A
Expansion slotN/A
User-accessible Flash slotNo
USB 2.0 portsUSB port type ‘A’, High Speed 2.0
Integrated I/O8 x 1GE
Expansion I/ON/A
Dedicated management portYes (To be shared with FirePOWER Services), 10/100/1000
Serial ports1 RJ-45 and Mini USB console
Solid-state drive80 GB mSata
Memory8 GB
System flash8 GB
System busMultibus architecture
Temperature32 to 104°F (0 to 40 °C)
Relative humidity10 to 90 percent noncondensing
AltitudeDesigned and tested for 0 to 10,000 ft (3048 m)
Acoustic
noise
 41.6 A-weighted decibels (dBA) type
67.2 dBA max
Temperature-13 to 158ºF (-25 to 70ºC)
Relative humidity10 to 90 percent noncondensing
AltitudeDesigned and tested for 0 to 15,000 ft (4572 m)
AC range line voltageExternal, 90 to 240 volts alternating current (VAC)
AC normal line voltage91 to 240 VAC
AC current0.25AC amps
AC frequency50/60 Hz
Dual-power suppliesNone
DC domestic line voltageN/A
DC international line voltageN/A
DC currentN/A
Steady state12V @3.0A
Maximum
peak
12V @ 5A
Maximum
heat dissipation
123 Btu/hr
Form factor1 rack unit (RU), 19-in. rack-mountable
Dimensions(H x W x D)1.72 x 17.2 x 11.288 in.
(4.369 x 43.688 x 28.672 cm)
Weight (with AC power supply)8 lb (3 kg)